Magna-Power ALx Series DC Electronic Load System
MagnaLOAD • Linear MOSFET Platform

ALx Series Linear MOSFET DC Electronic Loads

1.25 kW to 20 kW+ Power Ratings • Ultra-Wide Operating Range • 16-Bit Digital Control • Made in USA

Executive Summary

High-Density Linear Power Sinking with Zero Switching Noise

The ALx Series MagnaLOAD utilizes conventional linear MOSFET-based dissipative elements, allowing each instrument to achieve an exceptionally wide voltage-current operating envelope within its maximum rated power. Built on the thermal management innovations developed for Magna-Power’s high-density power processing platforms, the ALx Series features conservative thermal design ensuring continuous full-power operation in ambient environments up to 50°C.

27 Orderable Models 1.25 kW to 20 kW Power Levels Up to 1000 Vdc Input Voltage Up to 4800 Adc Input Current MagnaLINK™ Distributed DSP 16-Bit Control Resolution UL / CSA Listed • CE Mark Made in USA

Pure Linear Dissipation

Eliminates high-frequency switching noise injected back into devices under test. Essential for fuel cell, battery pack, and sensitive DC-DC converter characterization.

Shunt Regulator Mode

Acts as an intelligent, high-speed braking resistor on the DC bus to absorb regenerative energy and protect upstream power supplies or sources.

16-Bit Control & Sensing

Delivers precision Constant Current (CC), Constant Voltage (CV), Constant Power (CP), and Constant Resistance (CR) regulation with 0.0015% resolution.

Continuous 50°C Duty

Heavy-duty heat sink engineering and variable-speed fan cooling guarantee rated power without thermal derating in harsh industrial test bays.

Technical Capabilities

Engineered for Industrial Automation & Advanced R&D

From automated production test stations to research labs, ALx Series MagnaLOAD provides flexible programming, seamless master-slaving, and layered hardware protection.

MagnaLINK™ Control

MagnaLINK™ Distributed DSP Architecture

Utilizes a high-speed internal communication bus connecting distributed Digital Signal Processors. Field-tunable digital control loops allow users to optimize transient response and stability across diverse capacitive and inductive dynamic loads.

Scalable Power

Plug-and-Play Digital Master-Slaving

Expand current sinking capacity by interconnecting up to 16 units in parallel. A dedicated secondary current-sense bus shares real-time analog feedback with the master unit, displaying total aggregate system current and status seamlessly.

Isolated I/O

Isolated External User I/O Interface

Standard 25-pin D-sub connector provides isolated analog setpoints (0-10V), real-time monitoring outputs (0-10V), 5V digital I/O controls, and interlock pins referenced to earth ground. Analog sampling runs at 2 kHz for near-instantaneous feedback.

Model Selection Matrix

27 Standard Models Across 9 Power Levels

Select your model based on maximum voltage, current, and form factor requirements. Rack-mount packaging spans 1.25 kW to 2.5 kW (3U), while 5 kW to 20 kW configurations ship in rugged floor-standing cabinets (12U to 24U).

Model Number Max Power Max Voltage Max Current Package Type Min Voltage Max Resistance
ALx1.25-200-3001.25 kW200 Vdc300 Adc3U Rack-mount2.5 Vdc70.40 Ω
ALx1.25-500-1251.25 kW500 Vdc125 Adc3U Rack-mount6.0 Vdc448.00 Ω
ALx1.25-1000-37.51.25 kW1000 Vdc37.5 Adc3U Rack-mount7.5 Vdc1792.00 Ω
ALx2.5-200-6002.5 kW200 Vdc600 Adc3U Rack-mount2.5 Vdc70.40 Ω
ALx2.5-500-2502.5 kW500 Vdc250 Adc3U Rack-mount6.0 Vdc448.00 Ω
ALx2.5-1000-752.5 kW1000 Vdc75 Adc3U Rack-mount7.5 Vdc1792.00 Ω
ALx5-200-12005 kW200 Vdc1200 Adc12U Cabinet2.5 Vdc35.20 Ω
ALx5-500-5005 kW500 Vdc500 Adc12U Cabinet6.0 Vdc224.00 Ω
ALx5-1000-1505 kW1000 Vdc150 Adc12U Cabinet7.5 Vdc896.00 Ω
ALx7.5-200-18007.5 kW200 Vdc1800 Adc12U Cabinet2.5 Vdc23.47 Ω
ALx7.5-500-7507.5 kW500 Vdc750 Adc12U Cabinet6.0 Vdc149.33 Ω
ALx7.5-1000-2257.5 kW1000 Vdc225 Adc12U Cabinet7.5 Vdc597.33 Ω
ALx10-200-240010 kW200 Vdc2400 Adc12U Cabinet2.5 Vdc17.60 Ω
ALx10-500-100010 kW500 Vdc1000 Adc12U Cabinet6.0 Vdc112.00 Ω
ALx10-1000-30010 kW1000 Vdc300 Adc12U Cabinet7.5 Vdc448.00 Ω
ALx12.5-200-300012.5 kW200 Vdc3000 Adc24U Cabinet2.5 Vdc14.08 Ω
ALx12.5-500-125012.5 kW500 Vdc1250 Adc24U Cabinet6.0 Vdc89.60 Ω
ALx12.5-1000-37512.5 kW1000 Vdc375 Adc24U Cabinet7.5 Vdc358.40 Ω
ALx15-200-360015 kW200 Vdc3600 Adc24U Cabinet2.5 Vdc11.73 Ω
ALx15-500-150015 kW500 Vdc1500 Adc24U Cabinet6.0 Vdc74.67 Ω
ALx15-1000-45015 kW1000 Vdc450 Adc24U Cabinet7.5 Vdc298.67 Ω
ALx17.5-200-420017.5 kW200 Vdc4200 Adc24U Cabinet2.5 Vdc10.06 Ω
ALx17.5-500-175017.5 kW500 Vdc1750 Adc24U Cabinet6.0 Vdc64.00 Ω
ALx17.5-1000-52517.5 kW1000 Vdc525 Adc24U Cabinet7.5 Vdc256.00 Ω
ALx20-200-480020 kW200 Vdc4800 Adc24U Cabinet2.5 Vdc8.80 Ω
ALx20-500-200020 kW500 Vdc2000 Adc24U Cabinet6.0 Vdc56.00 Ω
ALx20-1000-60020 kW1000 Vdc600 Adc24U Cabinet7.5 Vdc224.00 Ω
Engineering Specifications

Comprehensive Performance & Operational Parameters

All parameters are measured and certified at maximum rated operating points in accordance with ISO calibration standards.

AC Input Ratings

  • Input Voltage (UI Option): 100-240 Vac (1-phase, 50-60 Hz) for 1.25 kW to 17.5 kW models
  • Input Voltage (UI2 Option): 200-240 Vac (1-phase, 50-60 Hz) for 20 kW models
  • Isolation: ±1500 Vac input to ground

Programming Accuracy & Slew

  • Voltage Accuracy: ±0.1% of full scale rating
  • Current Accuracy: ±0.2% of full scale rating
  • Power & Resistance Accuracy: ±0.3% of full scale rating
  • Current Rise Time: 2 ms (10% to 90% full scale)

Digital Interfaces & Protocols

  • Standard Connectivity: Dual USB Host (Front/Rear), RS485 (RJ45), MagnaLINK™ (RJ25)
  • Optional Fieldbuses: LXI TCP/IP Ethernet (+LXI), Modbus-TCP (+MTCP), EtherCAT (+ECAT), EtherNet/IP (+EIP), CANopen (+CAN), PROFINET (+PROF), GPIB (+GPIB)

Compliance & Safety

  • Safety Certifications: UL 61010-1:Ed.3, CSA C22.2 No. 61010-1, NRTL Listed (Nemko NA202512375)
  • EMC Standards: 2014/30/EU Directive, CISPR 22 / EN 55022 Class A
  • Environmental: CE Mark, RoHS Compliant, 0°C to 50°C Ambient Operating Temperature
Automated Integration

Native SCPI & Modbus Command Automation

Integrate ALx Series loads into automated test environments (ATE), Python scripts, LabVIEW, or factory PLCs with simple, standardized SCPI command sets.

import serial
import time

# Connect to MagnaLOAD ALx Series over Serial/USB
load = serial.Serial(port='COM4', baudrate=115200, timeout=1)

# Reset & Query Instrument Identification
load.write(b'*IDN?\n')
print("Connected to:", load.readline().decode().strip())

# Initialize parameters & turn on load input
load.write(b'VOLT 0\n')
load.write(b'CURR 0\n')
load.write(b'OUTP:START\n')

# Step through current load profile (Amperes)
setpoints = [50, 100, 200, 350]
for amps in setpoints:
    print(f"Sinking Current: {amps} A")
    load.write(f'CURR {amps}\n'.encode())
    load.write(b'MEAS:VOLT?\n')
    measured_v = load.readline().decode().strip()
    print(f"Measured Input Voltage: {measured_v} V")
    time.sleep(5)

# Safe shutdown
load.write(b'OUTP:STOP\n')
load.close()
Flag of the United States of America

Vertically Integrated Manufacturing in Flemington, New Jersey

Every ALx Series electronic load is designed, machined, assembled, and tested under one roof at Magna-Power's 73,500 sq-ft USA headquarters. In-house sheet metal fabrication, SMT printed circuit board assembly, and magnetics winding yield strict quality verification and predictable build cycles.

  • 100% full-power thermal burn-in and ISO-traceable calibration on every unit
  • Direct engineering-to-production oversight ensuring long-term spare parts availability
  • Worldwide regional service support centers across North America, Europe, UK, and Asia

Discuss Your Dynamic DC Loading Application

Contact our senior power electronics engineering team to analyze your voltage, current, slew rate, and interface requirements for the ALx Series MagnaLOAD.

Contact Us