ALx Series Linear MOSFET DC Electronic Loads
1.25 kW to 20 kW+ Power Ratings • Ultra-Wide Operating Range • 16-Bit Digital Control • Made in USA
High-Density Linear Power Sinking with Zero Switching Noise
The ALx Series MagnaLOAD utilizes conventional linear MOSFET-based dissipative elements, allowing each instrument to achieve an exceptionally wide voltage-current operating envelope within its maximum rated power. Built on the thermal management innovations developed for Magna-Power’s high-density power processing platforms, the ALx Series features conservative thermal design ensuring continuous full-power operation in ambient environments up to 50°C.
Pure Linear Dissipation
Eliminates high-frequency switching noise injected back into devices under test. Essential for fuel cell, battery pack, and sensitive DC-DC converter characterization.
Shunt Regulator Mode
Acts as an intelligent, high-speed braking resistor on the DC bus to absorb regenerative energy and protect upstream power supplies or sources.
16-Bit Control & Sensing
Delivers precision Constant Current (CC), Constant Voltage (CV), Constant Power (CP), and Constant Resistance (CR) regulation with 0.0015% resolution.
Continuous 50°C Duty
Heavy-duty heat sink engineering and variable-speed fan cooling guarantee rated power without thermal derating in harsh industrial test bays.
Engineered for Industrial Automation & Advanced R&D
From automated production test stations to research labs, ALx Series MagnaLOAD provides flexible programming, seamless master-slaving, and layered hardware protection.
MagnaLINK™ Distributed DSP Architecture
Utilizes a high-speed internal communication bus connecting distributed Digital Signal Processors. Field-tunable digital control loops allow users to optimize transient response and stability across diverse capacitive and inductive dynamic loads.
Plug-and-Play Digital Master-Slaving
Expand current sinking capacity by interconnecting up to 16 units in parallel. A dedicated secondary current-sense bus shares real-time analog feedback with the master unit, displaying total aggregate system current and status seamlessly.
Isolated External User I/O Interface
Standard 25-pin D-sub connector provides isolated analog setpoints (0-10V), real-time monitoring outputs (0-10V), 5V digital I/O controls, and interlock pins referenced to earth ground. Analog sampling runs at 2 kHz for near-instantaneous feedback.
27 Standard Models Across 9 Power Levels
Select your model based on maximum voltage, current, and form factor requirements. Rack-mount packaging spans 1.25 kW to 2.5 kW (3U), while 5 kW to 20 kW configurations ship in rugged floor-standing cabinets (12U to 24U).
| Model Number | Max Power | Max Voltage | Max Current | Package Type | Min Voltage | Max Resistance |
|---|---|---|---|---|---|---|
| ALx1.25-200-300 | 1.25 kW | 200 Vdc | 300 Adc | 3U Rack-mount | 2.5 Vdc | 70.40 Ω |
| ALx1.25-500-125 | 1.25 kW | 500 Vdc | 125 Adc | 3U Rack-mount | 6.0 Vdc | 448.00 Ω |
| ALx1.25-1000-37.5 | 1.25 kW | 1000 Vdc | 37.5 Adc | 3U Rack-mount | 7.5 Vdc | 1792.00 Ω |
| ALx2.5-200-600 | 2.5 kW | 200 Vdc | 600 Adc | 3U Rack-mount | 2.5 Vdc | 70.40 Ω |
| ALx2.5-500-250 | 2.5 kW | 500 Vdc | 250 Adc | 3U Rack-mount | 6.0 Vdc | 448.00 Ω |
| ALx2.5-1000-75 | 2.5 kW | 1000 Vdc | 75 Adc | 3U Rack-mount | 7.5 Vdc | 1792.00 Ω |
| ALx5-200-1200 | 5 kW | 200 Vdc | 1200 Adc | 12U Cabinet | 2.5 Vdc | 35.20 Ω |
| ALx5-500-500 | 5 kW | 500 Vdc | 500 Adc | 12U Cabinet | 6.0 Vdc | 224.00 Ω |
| ALx5-1000-150 | 5 kW | 1000 Vdc | 150 Adc | 12U Cabinet | 7.5 Vdc | 896.00 Ω |
| ALx7.5-200-1800 | 7.5 kW | 200 Vdc | 1800 Adc | 12U Cabinet | 2.5 Vdc | 23.47 Ω |
| ALx7.5-500-750 | 7.5 kW | 500 Vdc | 750 Adc | 12U Cabinet | 6.0 Vdc | 149.33 Ω |
| ALx7.5-1000-225 | 7.5 kW | 1000 Vdc | 225 Adc | 12U Cabinet | 7.5 Vdc | 597.33 Ω |
| ALx10-200-2400 | 10 kW | 200 Vdc | 2400 Adc | 12U Cabinet | 2.5 Vdc | 17.60 Ω |
| ALx10-500-1000 | 10 kW | 500 Vdc | 1000 Adc | 12U Cabinet | 6.0 Vdc | 112.00 Ω |
| ALx10-1000-300 | 10 kW | 1000 Vdc | 300 Adc | 12U Cabinet | 7.5 Vdc | 448.00 Ω |
| ALx12.5-200-3000 | 12.5 kW | 200 Vdc | 3000 Adc | 24U Cabinet | 2.5 Vdc | 14.08 Ω |
| ALx12.5-500-1250 | 12.5 kW | 500 Vdc | 1250 Adc | 24U Cabinet | 6.0 Vdc | 89.60 Ω |
| ALx12.5-1000-375 | 12.5 kW | 1000 Vdc | 375 Adc | 24U Cabinet | 7.5 Vdc | 358.40 Ω |
| ALx15-200-3600 | 15 kW | 200 Vdc | 3600 Adc | 24U Cabinet | 2.5 Vdc | 11.73 Ω |
| ALx15-500-1500 | 15 kW | 500 Vdc | 1500 Adc | 24U Cabinet | 6.0 Vdc | 74.67 Ω |
| ALx15-1000-450 | 15 kW | 1000 Vdc | 450 Adc | 24U Cabinet | 7.5 Vdc | 298.67 Ω |
| ALx17.5-200-4200 | 17.5 kW | 200 Vdc | 4200 Adc | 24U Cabinet | 2.5 Vdc | 10.06 Ω |
| ALx17.5-500-1750 | 17.5 kW | 500 Vdc | 1750 Adc | 24U Cabinet | 6.0 Vdc | 64.00 Ω |
| ALx17.5-1000-525 | 17.5 kW | 1000 Vdc | 525 Adc | 24U Cabinet | 7.5 Vdc | 256.00 Ω |
| ALx20-200-4800 | 20 kW | 200 Vdc | 4800 Adc | 24U Cabinet | 2.5 Vdc | 8.80 Ω |
| ALx20-500-2000 | 20 kW | 500 Vdc | 2000 Adc | 24U Cabinet | 6.0 Vdc | 56.00 Ω |
| ALx20-1000-600 | 20 kW | 1000 Vdc | 600 Adc | 24U Cabinet | 7.5 Vdc | 224.00 Ω |
Comprehensive Performance & Operational Parameters
All parameters are measured and certified at maximum rated operating points in accordance with ISO calibration standards.
AC Input Ratings
- Input Voltage (UI Option): 100-240 Vac (1-phase, 50-60 Hz) for 1.25 kW to 17.5 kW models
- Input Voltage (UI2 Option): 200-240 Vac (1-phase, 50-60 Hz) for 20 kW models
- Isolation: ±1500 Vac input to ground
Programming Accuracy & Slew
- Voltage Accuracy: ±0.1% of full scale rating
- Current Accuracy: ±0.2% of full scale rating
- Power & Resistance Accuracy: ±0.3% of full scale rating
- Current Rise Time: 2 ms (10% to 90% full scale)
Digital Interfaces & Protocols
- Standard Connectivity: Dual USB Host (Front/Rear), RS485 (RJ45), MagnaLINK™ (RJ25)
- Optional Fieldbuses: LXI TCP/IP Ethernet (+LXI), Modbus-TCP (+MTCP), EtherCAT (+ECAT), EtherNet/IP (+EIP), CANopen (+CAN), PROFINET (+PROF), GPIB (+GPIB)
Compliance & Safety
- Safety Certifications: UL 61010-1:Ed.3, CSA C22.2 No. 61010-1, NRTL Listed (Nemko NA202512375)
- EMC Standards: 2014/30/EU Directive, CISPR 22 / EN 55022 Class A
- Environmental: CE Mark, RoHS Compliant, 0°C to 50°C Ambient Operating Temperature
Native SCPI & Modbus Command Automation
Integrate ALx Series loads into automated test environments (ATE), Python scripts, LabVIEW, or factory PLCs with simple, standardized SCPI command sets.
import serial
import time
# Connect to MagnaLOAD ALx Series over Serial/USB
load = serial.Serial(port='COM4', baudrate=115200, timeout=1)
# Reset & Query Instrument Identification
load.write(b'*IDN?\n')
print("Connected to:", load.readline().decode().strip())
# Initialize parameters & turn on load input
load.write(b'VOLT 0\n')
load.write(b'CURR 0\n')
load.write(b'OUTP:START\n')
# Step through current load profile (Amperes)
setpoints = [50, 100, 200, 350]
for amps in setpoints:
print(f"Sinking Current: {amps} A")
load.write(f'CURR {amps}\n'.encode())
load.write(b'MEAS:VOLT?\n')
measured_v = load.readline().decode().strip()
print(f"Measured Input Voltage: {measured_v} V")
time.sleep(5)
# Safe shutdown
load.write(b'OUTP:STOP\n')
load.close()
Vertically Integrated Manufacturing in Flemington, New Jersey
Every ALx Series electronic load is designed, machined, assembled, and tested under one roof at Magna-Power's 73,500 sq-ft USA headquarters. In-house sheet metal fabrication, SMT printed circuit board assembly, and magnetics winding yield strict quality verification and predictable build cycles.
- 100% full-power thermal burn-in and ISO-traceable calibration on every unit
- Direct engineering-to-production oversight ensuring long-term spare parts availability
- Worldwide regional service support centers across North America, Europe, UK, and Asia
Discuss Your Dynamic DC Loading Application
Contact our senior power electronics engineering team to analyze your voltage, current, slew rate, and interface requirements for the ALx Series MagnaLOAD.